40 deficiencies across all inspections. Filter by severity or status.
| D-1015-5 | Pull-station label faded (parking garage) | INSP-1015 | Skyline Towers HOA | fire_safety | Low | Open | May 16, 2026 |
| D-1015-4 | Magnet hold-open device failed on stairwell 9 | INSP-1015 | Skyline Towers HOA | fire_safety | Medium | In remediation | May 16, 2026 |
| D-1042-8 | Hood suppression cylinder gauge low (kitchen) | INSP-1042 | Brookhaven Manor | fire_safety | Medium | In remediation | May 16, 2026 |
| D-1042-7 | Standpipe inspection seal broken (lobby riser) | INSP-1042 | Brookhaven Manor | fire_safety | Medium | Open | May 16, 2026 |
| D-1062-3 | GFCI test interval lapsed on Plant A outlets | INSP-1062 | Cedar Industries | electrical | Medium | Open | May 16, 2026 |
| D-1010-4 | Storage closet blocked by holiday decorations | INSP-1010 | Skyline Towers HOA | housekeeping | Low | Closed | May 16, 2026 |
| D-1100-3 | Energy-isolation diagram missing from Lc-2 | INSP-1100 | Highland Welding | osha | Medium | Open | May 16, 2026 |
| D-1100-2 | Annual LOTO training overdue for one operator | INSP-1100 | Highland Welding | osha | Medium | Open | May 16, 2026 |
| D-1055-3 | Welding curtain missing in bay 2 | INSP-1055 | Bluegrass Steel Works | osha | Medium | Open | May 16, 2026 |
| D-1055-2 | PPE training records lapsed for two operators | INSP-1055 | Bluegrass Steel Works | osha | Medium | Open | May 16, 2026 |
| D-1030-3 | Condenser coil debris | INSP-1030 | Granite State Foods | hvac | Low | Resolved | May 16, 2026 |
| D-1030-2 | Refrigerant pressure 8% high on cooler A | INSP-1030 | Granite State Foods | hvac | Medium | In remediation | May 16, 2026 |
| D-1015-3 | Lobby exit signage cleaning needed | INSP-1015 | Skyline Towers HOA | housekeeping | Low | Resolved | May 16, 2026 |
| D-1015-2 | Fire pump test log not updated (April) | INSP-1015 | Skyline Towers HOA | documentation | Medium | In remediation | May 16, 2026 |
| D-1065-2 | Floor markings worn in welding bay aisles | INSP-1065 | Heartland Fabrication | housekeeping | Low | Open | May 16, 2026 |
| D-1062-2 | Conduit corrosion on Plant A north wall | INSP-1062 | Cedar Industries | electrical | Low | Open | May 16, 2026 |
| D-1042-6 | Fire-safety training overdue for two staff | INSP-1042 | Brookhaven Manor | documentation | Medium | Open | May 16, 2026 |
| D-1042-5 | Evacuation map outdated (memory care entrance) | INSP-1042 | Brookhaven Manor | documentation | Low | Open | May 16, 2026 |
| D-1020-5 | Panel clearance blocked by inventory | INSP-1020 | Westbrook Distribution | electrical | High | In remediation | May 16, 2026 |
| D-1025-3 | Improper stacking in chemical storage | INSP-1025 | Riverline Logistics | compliance | High | In remediation | May 16, 2026 |